CVE-2014-5419

GE Multilink Use of Hard-coded Cryptographic Key

10.0 high EPSS 2.42%

Published 17 Jan 2015 Updated 4 Nov 2025 CNA: icscert

Description

GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier use the same RSA private key across different customers' installations, which makes it easier for remote attackers to obtain the cleartext content of network traffic by reading this key from a firmware image and then sniffing the network.

Severity (CVSS)

10.0 high CVSS 2.0 from icscert (CNA)
AV:N/AC:L/Au:N/C:C/I:C/A:C
Attack vector
network: an attacker can reach the vulnerable part over the network
Attack complexity
low
Authentication
none: the attacker does not need to log in
Impact
confidentiality complete, integrity complete, availability complete

Exploitation

EPSS 2.42%: the probability of exploitation activity in the next 30 days, from the EPSS model of FIRST. The score is higher than 84.8% of all scored CVEs. Scores of 26 Nov 2026.

Weakness

  • CWE-321 Use of Hard-coded Cryptographic Key

Affected products

As the CNA lists them.

ProductVersions
Multilink ML800/1200/1600/2400
affected up to and including 4.2.1
Other versions: unaffected
ML810/3000/3100 series switch
affected up to and including 5.2.0
Other versions: unaffected

Is my server affected?

This CVE is in Multilink ML800/1200/1600/2400 of GE, which Linux distributions and language package managers do not ship. The advisory of the vendor is in the references below.

PatchBrief matches the package lists of Linux servers and containers against the Trivy vulnerability database, which does not list this product.

References

Advisories

Other references

Source: the record CVE-2014-5419 of the CVE List (CVE Program), CVE Terms of Use; EPSS of FIRST; the CWE catalog of MITRE, CWE Terms of Use. The text of the record is shown as published. Data sources and licences.